This site uses cookies to improve your browsing experience. we’ll assume you’re OK to continue. If you want to read more about this, please clickPRIVACY ,thank you.
- AC Current Ranges: 6A / 15A / 60A / 150A / 300A (±3% of full scale).
- AC Voltage Ranges: 300V / 600V (±3% of full scale).
- DC Voltage Range: 75V (±3% of full scale).
- Resistance Range: 2kΩ (±3% of scale length).
- Frequency Response:
- 50/60Hz for ACA 6A.
- 50-400Hz for ACA 15A / 60A / 150A / 300A.
- Conductor Size: 38mm max.
- Dimensions: 230mm × 72mm × 37mm.
- Weight: Approx. 420g (including battery).
- Safety Standards: EN 61010-1 CAT II 600V, EN 61010-2-32.
- Earth resistance measurement: 0-12Ω, 0-120Ω, 0-1200Ω.
- Earth voltage measurement: 0-30V AC (40-500Hz).
- 2mA measuring current, allowing testing without tripping earth leakage breakers.
- Battery-operated with a battery life indicator.
- Calibration performed with supplied test leads.
- Supports both two-wire and three-wire measurement systems.
- Compact design: 175mm × 85mm × 75mm, weighing approximately 600g.
- Safety standards: EN 61010-1 CAT IV 30V, EN 61326-1.
- Earth resistance measurement: 0-20Ω, 0-200Ω, 0-2000Ω.
- Earth voltage measurement: 0-200V AC (40-500Hz).
- 2mA measuring current, allowing testing without tripping earth leakage breakers.
- Battery-operated with a low battery indicator.
- Data hold function for easy readings.
- Over-range indication: “1” (MSD).
- Calibration performed with supplied test leads.
- Safety standards: EN 61010-1 CAT III 300V, IEC 61557-1, IEC 61557-5, EN 61326-1.
- Compact design: 170mm × 165mm × 92mm, weighing approximately 1040g.
- Earth resistance measurement: 0-20Ω, 0-200Ω, 0-2000Ω.
- Earth voltage measurement: 0-200V AC (40-500Hz).
- 2mA measuring current, allowing testing without tripping earth leakage breakers.
- Battery-operated with a low battery indicator.
- Data hold function for easy readings.
- Over-range indication: “1” (MSD).
- **Calibration performed with supplied test leads.
- Safety standards: IEC 1010 CAT III 200V.
- Compact design: 163mm × 100mm × 50mm, weighing approximately 480g.
- High-quality shock-resistant meter head for stable readings.
- Measures earth resistance and ground voltage accurately.
- Automatic timer function for long-duration testing (about 3-5 minutes).
- Battery-operated with a battery check function.
- Calibration performed with supplied test leads.
- Safety standard compliance: EN 61010-1 CAT II 30V.
- Compact and lightweight design (163mm × 100mm × 50mm, approx. 460g).
- Comes with accessories: test leads (red-15m, yellow-10m, green-5m), auxiliary earth spikes, carrying case, and batteries.