1. Wide Measurement Range: Measures up to 1000 A for both ACA (Alternating Current Amperes) and DCA (Direct Current Amperes), with two ranges for each (600 A, 1000 A).
2. Smart Functionality: Features intelligent functions that automatically select ACV, DCV, resistance, diode, continuity beeper, capacitance, ACA, and DCA measurements with auto range.
3. High Accuracy and Resolution: Provides high resolution with 6000 counts A/D and accurate readings for various measurements.
4. User-Friendly Design: Includes a bright LCD display, data hold function, and auto power off to save battery life.
5. Safety Compliance: Meets IEC 1010 CAT III 1000 V and CAT IV 600 V safety standards, ensuring reliable and safe operation.
1. Wide Measurement Range: Measures up to 1000 A for both ACA (Alternating Current Amperes) and DCA (Direct Current Amperes), with two ranges for each (600 A, 1000 A).
2. Smart Functionality: Features intelligent functions that automatically select ACV, DCV, resistance, diode, continuity beeper, capacitance, ACA, and DCA measurements with auto range.
3. High Accuracy and Resolution: Provides high resolution with 6000 counts A/D and accurate readings for various measurements.
4. User-Friendly Design: Includes a bright LCD display, data hold function, and auto power off to save battery life.
5. Safety Compliance: Meets IEC 1010 CAT III 1000 V safety standards, ensuring reliable and safe operation.
•Microprocessor-controlled.
•ACV auto-detection function on 3 insulation ranges (250/500/1000V) and low Ω ragne before pressing the TEST button.
•68 x 34mm large LCD display.
•3½ digital LCD (2000 counts) a LCD indicated instrument for insulation(MΩ), continuity (Ω) and AC voltage.
•Three insulation test voltages(DC V) : 250V, 500V, 1000V.
•Auto ranging.
•Auto power off function.
•Auto data hold function.
•Rel function (ohm only)
•Continuity buzzer.
•External AC voltage warning.
•Automatic circuit discharge.
•BS 16th edition.
- Non-contact detection for enhanced safety.
- Two functions in one: Phase sequence detection and open phase detection.
- Brightness switch for visibility in dim areas or direct sunlight.
- Magnetic back cover for easy attachment to AC distribution panels.
- Detection range: 75V to 1000V AC.
- Conductor size: 1mm to 33mm.
- Frequency range: 45Hz to 65Hz.
- Auto power-off after 5 minutes of inactivity.
- Low battery warning when power drops below 4.6V.
- Jaw opening: 33mm max.
- Safety Standards: EN 61010-1 CAT III 1000V / CAT IV 600V.
- Three functions in one: Identifies phase sequence, open phase, and motor rotation.
- Large alligator clips for easy attachment to switchboard terminals.
- Ideal for conveyor lines, pump systems, and interconnected motors.
- Contact-type measurement for accurate phase detection.
- All-electronic circuit design (non-mechanical) for durability.
Specifications:
- Input Voltage: 100-600V AC.
- Frequency Range: 45-70 Hz.
- Power Source: 9V (6F22) × 1.
- Power Consumption: Approx. 14mA.
- Dimensions: 150mm × 72mm × 35mm.
- Weight: Approx. 212g (including battery).
- Safety Standard: EN 61010-1 CAT III 600V.
- Two functions in one: Identifies phase sequence and open phase.
- Large alligator clips for easy attachment to switchboard terminals.
- LED indicators allow quick identification of phase status.
- Push-button switch minimizes damage due to accidental misuse.
- Checks a wide range of three-phase power sources.
- Compact and durable design for long-term use.
Specifications:
- Input Voltage: 90V-600V AC.
- Frequency Response: 50/60 Hz.
- Operating Temperature: 0°C ~ 40°C.
- Storage Temperature: -10°C ~ 50°C.
- Cord Length: 1.1m each (Red, White, Black).
- Dimensions: 134mm × 85mm × 45mm.
- Weight: Approx. 510g.
- Safety Standard: EN 61010-1 CAT II 600V.
- 200mV and 2V full-range input sensitivity.
- Supports single 9V battery or ±5V DC power supply.
- Built-in low battery indicator and automatic polarity display.
- Selectable decimal point position.
- Low power consumption (typically below 20mW).
- High input impedance (>1MΩ).
- Zero voltage input ensures a zero display across all ranges.
- Supports true differential input or single-ended input.
- Self-installation capability with optional mounting frame.
- Complies with standards: EN 50081-1, EN 50082-1, EN 55022, EN 61000-4-2, IEC 801-3.
- 4-20mA input sensitivity, ideal for industrial applications.
- Supports single 9V battery or ±5V DC power supply.
- Built-in low battery indicator and automatic polarity display.
- Selectable decimal point position.
- Low power consumption (typically below 20mW).
- High input impedance (>1MΩ).
- Zero voltage input ensures a zero display across all ranges.
- Supports true differential input or single-ended input.
- Self-installation capability with optional mounting frame.
- Complies with standards: EN 50081-1, EN 50082-1, EN 55022, EN 61000-4-2, IEC 801-3.
- 19 resistance ranges from 1MΩ to 500GΩ.
- High accuracy with resistance tolerances ranging from ±1% to ±1000ppm/°C.
- Maximum working voltage: DC 10kV.
- Low power coefficient: Below 3W.
- Operating temperature: -30°C to 75°C.
- Binding post terminals for secure connections.
- Durable construction for long-term reliability.
Specifications:
- Dimensions: 430mm × 324mm × 127mm.
- Weight: Approx. 5200g.
- Voltage detection range: 50V~1000V AC.
- Frequency range: 50~500 Hz.
- Non-contact detection for enhanced safety.
- Vibration alarm and LED indicator when voltage is present.
- Flashlight function for use in dim environments.
- ON/OFF switch to extend battery life.
- IP65 protection rating for durability.
- Measurement category: CAT III 1000V.
- Operating conditions:
- Temperature: 0~40°C.
- Humidity: Less than 80% R.H..
- Altitude: Up to 2000m.
- Power source: 1.5V (AAA) × 2.
- Dimensions: 167mm × 27mm × 29.5mm.
- Weight: Approx. 51g (including batteries).
- Contact-type detection for accurate voltage measurement.
- LED indicator and audible alarm when voltage is present.
- Designed for AC/DC voltage detection.
- Suitable for bare wires or conductors.
- Self-test function to verify proper operation before use.
- Low power consumption for extended battery life.
- Compact and lightweight design for easy portability.
- Indoor use only.
Specifications:
- Voltage Detection Range: AC 12V ~ 600V DC 12V ~ 600V.
- Frequency Range: 30 ~ 330 Hz.
- Measurement Category: CAT III 600V.
- Operating Temperature: 0~40°C.
- Humidity: Less than 80% R.H..
- Altitude: Up to 2000m (6500 feet).
- Pollution Degree: 2.
- Dimensions: 148mm × 27mm × 25mm.
- Weight: Approx. 57g (including batteries).
- Power Source: 1.5V (AAA) × 2.
- Safety Standards: EN 61010-1, EN 61326-1, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8.