SEW

  • Read More
    6500LC.jpg

    6500 LC-Loop Calibrator

    • 4-20mA (1kΩ load, 24V Loop Supply).
    • 0.025% Basic Accuracy.
    • Simple Operation Interface.
    • Auto Ramp and Step Functions.
    • 0-20mA, 0-24mA selectable.
    • Incremental percentage setting : 0-100%.
    • Warning beeper when output is open.
    • 0-24V output.
    • The minimum load of 20kΩ on voltage mode.
  • Read More
    1651in Digital nsulation Tester.jpg

    1651IN Digital (Up to 1kV) Insulation Tester

    •Microprocessor-controlled.
    •ACV auto-detection function on 3 insulation ranges (250/500/1000V) and low Ω ragne before pressing the TEST button.
    •68 x 34mm large LCD display.
    •3½ digital LCD (2000 counts) a LCD indicated instrument for insulation(MΩ), continuity (Ω) and AC voltage.
    •Three insulation test voltages(DC V) : 250V, 500V, 1000V.
    •Auto ranging.
    •Auto power off function.
    •Auto data hold function.
    •Rel function (ohm only)
    •Continuity buzzer.
    •External AC voltage warning.
    •Automatic circuit discharge.
    •BS 16th edition.
  • Read More
    890PR-Non-Contact Phase Sequence Indicator.jpg

    890PR Non-Contact Phase Sequence Indicator

    - Non-contact detection for enhanced safety.
    - Two functions in one: Phase sequence detection and open phase detection.
    - Brightness switch for visibility in dim areas or direct sunlight.
    - Magnetic back cover for easy attachment to AC distribution panels.
    - Detection range: 75V to 1000V AC.
    - Conductor size: 1mm to 33mm.
    - Frequency range: 45Hz to 65Hz.
    - Auto power-off after 5 minutes of inactivity.
    - Low battery warning when power drops below 4.6V.
    - Jaw opening: 33mm max.
    - Safety Standards: EN 61010-1 CAT III 1000V / CAT IV 600V.
  • Read More
    ST-860-Contact-Type Phase Sequence Indicator.jpg

    ST-860 Contact-Type Phase Sequence Indicator

    - Three functions in one: Identifies phase sequence, open phase, and motor rotation.
    - Large alligator clips for easy attachment to switchboard terminals.
    - Ideal for conveyor lines, pump systems, and interconnected motors.
    - Contact-type measurement for accurate phase detection.
    - All-electronic circuit design (non-mechanical) for durability.
    Specifications:
    - Input Voltage: 100-600V AC.
    - Frequency Range: 45-70 Hz.
    - Power Source: 9V (6F22) × 1.
    - Power Consumption: Approx. 14mA.
    - Dimensions: 150mm × 72mm × 35mm.
    - Weight: Approx. 212g (including battery).
    - Safety Standard: EN 61010-1 CAT III 600V.
  • Read More
    ST-850-Contact-Type Phase Sequence Indicator.jpg

    ST-850 Contact-Type Phase Sequence Indicator

    - Two functions in one: Identifies phase sequence and open phase.
    - Large alligator clips for easy attachment to switchboard terminals.
    - LED indicators allow quick identification of phase status.
    - Push-button switch minimizes damage due to accidental misuse.
    - Checks a wide range of three-phase power sources.
    - Compact and durable design for long-term use.
    Specifications:
    - Input Voltage: 90V-600V AC.
    - Frequency Response: 50/60 Hz.
    - Operating Temperature: 0°C ~ 40°C.
    - Storage Temperature: -10°C ~ 50°C.
    - Cord Length: 1.1m each (Red, White, Black).
    - Dimensions: 134mm × 85mm × 45mm.
    - Weight: Approx. 510g.
    - Safety Standard: EN 61010-1 CAT II 600V.
  • Read More
    ST312V--Digital Panel Meter.png

    ST-312V Digital Panel Meter

    - 200mV and 2V full-range input sensitivity.
    - Supports single 9V battery or ±5V DC power supply.
    - Built-in low battery indicator and automatic polarity display.
    - Selectable decimal point position.
    - Low power consumption (typically below 20mW).
    - High input impedance (>1MΩ).
    - Zero voltage input ensures a zero display across all ranges.
    - Supports true differential input or single-ended input.
    - Self-installation capability with optional mounting frame.
    - Complies with standards: EN 50081-1, EN 50082-1, EN 55022, EN 61000-4-2, IEC 801-3.
  • Read More
    ST312A-Digital Panel Meter.png

    ST-312A Digital Panel Meter

    - 4-20mA input sensitivity, ideal for industrial applications.
    - Supports single 9V battery or ±5V DC power supply.
    - Built-in low battery indicator and automatic polarity display.
    - Selectable decimal point position.
    - Low power consumption (typically below 20mW).
    - High input impedance (>1MΩ).
    - Zero voltage input ensures a zero display across all ranges.
    - Supports true differential input or single-ended input.
    - Self-installation capability with optional mounting frame.
    - Complies with standards: EN 50081-1, EN 50082-1, EN 55022, EN 61000-4-2, IEC 801-3.
  • Read More
    RCB1-Resistor Calibration Box.png

    RCB-1 Resistor Calibration Box

    - 19 resistance ranges from 1MΩ to 500GΩ.
    - High accuracy with resistance tolerances ranging from ±1% to ±1000ppm/°C.
    - Maximum working voltage: DC 10kV.
    - Low power coefficient: Below 3W.
    - Operating temperature: -30°C to 75°C.
    - Binding post terminals for secure connections.
    - Durable construction for long-term reliability.
    Specifications:
    - Dimensions: 430mm × 324mm × 127mm.
    - Weight: Approx. 5200g.
  • Read More
    LVD25-Low Voltage Detector.png

    LVD-25 Low Voltage Detector

    - Voltage detection range: 50V~1000V AC.
    - Frequency range: 50~500 Hz.
    - Non-contact detection for enhanced safety.
    - Vibration alarm and LED indicator when voltage is present.
    - Flashlight function for use in dim environments.
    - ON/OFF switch to extend battery life.
    - IP65 protection rating for durability.
    - Measurement category: CAT III 1000V.
    - Operating conditions:
    - Temperature: 0~40°C.
    - Humidity: Less than 80% R.H..
    - Altitude: Up to 2000m.
    - Power source: 1.5V (AAA) × 2.
    - Dimensions: 167mm × 27mm × 29.5mm.
    - Weight: Approx. 51g (including batteries).
  • Read More
    LVD20-AC _ DC Voltage Detector.png

    LVD-20 Contact Voltage Detector

    - Contact-type detection for accurate voltage measurement.
    - LED indicator and audible alarm when voltage is present.
    - Designed for AC/DC voltage detection.
    - Suitable for bare wires or conductors.
    - Self-test function to verify proper operation before use.
    - Low power consumption for extended battery life.
    - Compact and lightweight design for easy portability.
    - Indoor use only.
    Specifications:
    - Voltage Detection Range: AC 12V ~ 600V DC 12V ~ 600V.
    - Frequency Range: 30 ~ 330 Hz.
    - Measurement Category: CAT III 600V.
    - Operating Temperature: 0~40°C.
    - Humidity: Less than 80% R.H..
    - Altitude: Up to 2000m (6500 feet).
    - Pollution Degree: 2.
    - Dimensions: 148mm × 27mm × 25mm.
    - Weight: Approx. 57g (including batteries).
    - Power Source: 1.5V (AAA) × 2.
    - Safety Standards: EN 61010-1, EN 61326-1, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8.
  • Read More
    LVD18-Volt-Finger.png

    LVD18-Volt-Finger Detector / Driver

    - Dual detection modes: Contact and non-contact voltage detection.
    - Voltage detection range: 50V~600V AC.
    - Frequency range: 50~500 Hz.
    - Continuity test and basic driver function.
    - Bright LED and audible alarm when voltage is present.
    - Flashlight function for use in dim environments.
    - Compact and lightweight design for easy portability.
    - Measurement category: CAT III 600V.
    - Operating conditions:
    - Temperature: 0~40°C.
    - Humidity: Less than 80% R.H..
    - Altitude: Up to 2000m.
    - Power source: 1.5V (AAA) × 2.
    - Dimensions: 165mm × 27mm × 22mm.
    - Weight: Approx. 46g (including batteries).
    - Safety Standards: EN 61010-1 CAT III 600V, EN 61326-1.
  • Read More
    LVD-17-Low Voltage Detector.png

    LVD-17 Low Voltage Detector

    - Voltage detection range: 5V~1000V AC.
    - Frequency range: 50~500 Hz.
    - Non-contact detection for enhanced safety.
    - Adjustable sensitivity using a thumbwheel.
    - LED indication for battery condition.
    - Identifies Hot and Neutral wires.
    - Compact and lightweight design for easy portability.
    - Measurement category: CAT IV 1000V.
    - Operating conditions:
    - Temperature: 0~40°C.
    - Humidity: Less than 80% R.H..
    - Altitude: Up to 2000m.
    - Power source: 1.5V (AAA) × 1.
    - Dimensions: 142mm × 28mm × 27mm.
    - Weight: Approx. 39g (including battery).
    - Safety Standards: EN 61010-1 CAT IV 1000V, EN 61326-1.